Audiometry Definitions
Aims to determine the required settings for the treatment of the audiometry tests. In this screen the settings for the audiometry item will be determined; we will indicate the opinions for the automatic interpretation of this exam in the folders; Portaria Method 19, Clinical, Pereira, INSS, Davis & Silverman, Fowler and Type of Loss.
Audiometry Guide
Valid information:
- Yes, when you press the button register Audiometry of medical care, in the entry window of the model will be suggested the date of the last examination audiométrico conducted by the patient. This examination may or may not be compared with the survey reference audiométrico as the next field in the entry window.
- N-no, at the moment of issuing the report the user shall inform the exam date you want to list.
Consider the absence of the average
Used to calculate the averages 0.5 .1 .2 frequencies and 3, 4, 6 and airway also the calculation of logoaudiometria. Valid information:
- Yes, for the calculation of the average will be considered missing frequencies that is, those that are Unanswered (green).
- No, the average will be calculated excluding missing frequencies that is, those that are Unanswered (green).
To cater for cases where the audiometry reports are listed in printers that have black ink only, this field allows you to set the print form of the Green results when frequencies their response (SR), as follows:
- -Value corresponds to previous form, that is, prints the value without reply in green.
- Acronym SR (no reply)-the values without reply will be replaced by MR green in color.
Used at the launch of the values of Bone frequencies:
- Yes, allows the values for frequencies via superior bone (worse) than the air.
- N-no, the values of the bone via cannot be higher than those of the airway.
Match the time of hearing that home must be fulfilled for audiométrico examination. This value should be at least 2:0 pm. To register a new audiométrico exam, will be proposed this value.
Inform the name of the default template of audiometry where will be presented the charts and results. The official model is SMAU002.GER. In audiometric tests results window you will find the Audiometry button to generate the report.
Inform the name of the default template to be used in the issuance of tracking model audiometry. The official model is SMAU003.GER. In audiometric tests results window you will find the button Evolution to generate this report. Will display the selected results.
Offers fixed line on the chart
Allows you to list a boundary line of normalcy on audiométrico examination record.
- Yes, will be presented in the graphs of audiometry a boundary line of normality.
- N-will not be presented the boundary line.
Allows you to define what part of the line graph will be displayed. The allowed values are between -10 to 130.
- C-the frequencies in KHZ (0.25; 0.5; 1; 2; 3; 4; 6; 8) are printed above the graph audiométrico.
- B-the frequencies in KHZ (0.25; 0.5; 1; 2; 3; 4; 6; 8) will be printed below the graph audiométrico
Valid information:
Yes, after generating the audiometry, model this model of the questionnaire will be generated.
N-no, will be raised only the model of audiometry.
Valid information:
- Not use the information related to this type of additional examination shall not be made available on audiometry.
- I-Only the result items-information on this additional examination will only be made available in the folder items.
- P-main tab and the tab items-are the Audiometry and result items.
Valid information:
- Not use the information related to this type of additional examination shall not be made available on audiometry.
- I-Only the result items-information on this additional examination will only be made available in the folder items.
- P-main tab and the tab items-are the Audiometry and result items.
Lim. Colour temp. Logoaudiometria
Enter a value to limit the intensity in his logoaudiometria. The "intensity" is located in Medicine/Audiometry/results, Result items folder, subfolder Logoaudiometria or Logoaudiometria folder, as indicated in the previous provision. The frequencies used to calculate the threshold are: 0.5-0.25-1-2.
Important
If the field is zero-valued, there will be no limit.
Features Immitanciometry Examinations Which Demonstrate
The immitanciometry examinations which demonstrate is the test which checked the conditions of the middle ear, more specifically the eardrum system-fusion, and via the Stapedius Reflex. Valid information:
- Yes, the results will be made available to items sub-tab for additional examination information of immitanciometry examinations which demonstrate.
- N-no, this additional examination will not be available.
Immitanciometry examinations which demonstrate
Inform the immitanciometry examinations which demonstrate the model that will be listed from the registration window of audiometric tests results, through the [Immitanciometry examinations which demonstrate]. The print template corresponds to SMAU004.GER.
Valid information:
- Yes, the results will be made available to items sub-tab for additional examination information of immitanciometry examinations which demonstrate.
- N-no, this additional examination will not be available.
The Weber method uses the tuning fork where is installed in the midline of the front, the skullcap or with the incisor teeth. If the sound is perceived equally in both ears, hearing is normal or hearing loss is similar bilaterally and, in this case, it is said that Weber is indifferent. If the lateralizar sound to the ear of better hearing loss is sensorineural in the affected side. If the lateralizar sound to the ear more committed, the conductive loss is in the latter. Valid information:
- Yes, the results will be made available to items sub-tab Weber for additional examination information.
- N-no, this additional examination will not be available.
Valid information:
- Yes, in audiometry definitions to guide clinical method will be available with its opinions and the results of tests on the methods tab fields: Clinical Opinion OD and OE.
- N-no, the definitions of audiometry to guide clinical method will not be available and the results of tests on the Methods the fields: Clinical Opinion OD and OE.
Valid information:
- Yes, the definitions of the audiometry Pereira will be made with Method guide their opinions and the results of tests on the methods tab fields: Pereira and Opinion OD OE.
- N-no, in audiometry definitions the Method tab will not be available and the Parker directory of results the Methods tab fields: Pereira and Opinion OD OE.
Valid information:
- Yes, in audiometry definitions the Method tab will be provided with SOCIAL SECURITY its opinions and the results of tests on the methods tab fields: SOCIAL and Opinion OD OE.
- N-no, in audiometry definitions the Method tab will not be available and the SOCIAL SECURITY record of results the Methods tab fields: SOCIAL and Opinion OD OE.
Valid information:
- Yes, the definitions of the audiometry loss Guide will be available with its opinions and the results of tests on the methods tab fields: type of loss OD and OE.
- N-no, audiometry settings the tab type of loss will not be available as also in other windows.
Valid information:
- Yes, the definitions of the Davis Method guide & audiometry Silverman will be available with its opinions and the results of tests on the methods tab fields: D & S Opinion OD and OE.
- N-no, the definitions of the Davis Method guide & audiometry Silverman won't be made available but also on other windows.
Valid information:
- Yes, the definitions of the Fowler Method guide audiometry will be available with its opinions and the results of tests on the methods tab fields: Fowler-OD Opinion and OE.
- N-no, in audiometry definitions the Method tab will not be available as Fowler also in other windows.
Indicate whether the audiometry results will be considered by ear or by examination.
- 0-consider forExamination Defines that the results of the examination shall be for audiometry.
- 1-consider for Ear Sets the audiometry results are separated by ear.
Important
Every time you change this field to ' 0 '-consider for examination to ' 1 '-consider for Ear, pressing the change button will be held a conversion in the information of the R108RES fields. TipExa, R108RES. NorAlt, R108RES. EvoRes and R108RES. SitRes (fields of the audiometry results right ear) will be duplicated for the fields TipEsq, ResEsq, EvoEsq and OcuEsq, respectively (fields for left ear).
Result Immitanciometry Examinations Which Demonstrate
When the field is with value "C-Complicance":
- On the window > > Audiometry Medical results, Results items tab, Sub-Immitanciometry examinations which demonstrate the Guide, are available fields that allow report compliancia values.
- Will be hidden fields of the frequencies ( -500 to +200) of the audiometry Results window, the tab Items, Immitanciometry examinations which demonstrate and model sub-tab SMAU004.GER.
When the field is with value "F-Frequency":
- On the window > > Audiometry Medical results, Results items tab, Sub-Immitanciometry examinations which demonstrate the Guide, are available fields that will allow you to inform the frequency values (from -500 to +200), and the SMAU004 model. GER the graph will be assembled from the values reported on these frequencies.
- Will be hidden fields concerning the complicance audiometry Results window, the tab Items, Immitanciometry examinations which demonstrate the sub-tab.
Portaria Method Guide 19
Indicate the opinion that will be used on automatic interpretation of the test. The use of the opinion should be 8 (Ordinance 19).
Suggestive of PAINPSE (hearing loss Induced by High sound pressure levels)
Indicate the opinion that will be used on automatic interpretation of the test. The use of the opinion should be 8 (Ordinance 19).
Not suggestive of PAINPSE (hearing loss Induced by High sound pressure levels)
Indicate the opinion that will be used on automatic interpretation of the test. The use of the opinion should be 8 (Ordinance 19).
Within limits: Indicate the opinion that will be used on automatic interpretation of the test. The use of the opinion should be 8 (Ordinance 19).
PAINPSE Trigger (hearing loss Induced by High sound pressure levels)
Indicate the opinion that will be used on automatic interpretation of the test. The use of the opinion should be 8 (Ordinance 19).
PAINPSE aggravation (hearing loss Induced by High sound pressure levels)
Indicate the opinion that will be used on automatic interpretation of the test. The use of the opinion should be 8 (Ordinance 19).
Clinical Method Guide
Inform the sound corresponding to the 0-Degree normal. The use of the opinion should be 9 (clinical method).
Inform the sound corresponding to the Grade 1-mild loss. The use of the opinion should be 9 (clinical method).
Inform the sound corresponding to the Grade 2-moderate loss. The use of the opinion should be 9 (clinical method).
Inform the sound corresponding to the Grade 3-moderate/severe loss. The use of the opinion should be 9 (clinical method).
Inform the sound corresponding to the Grade 4-severe loss. The use of the opinion should be 9 (clinical method).
Inform the sound corresponding to the 5-Degree deep loss. The use of the opinion should be 9 (clinical method).
Inform the sound corresponding to the type Anacusia. The use of the opinion should be 9 (clinical method). Anacusia means the complete loss of hearing.
Method Guide Pant
Inform the sound corresponding to the 0-Degree normal. The use of the opinion should be 10 (Pereira).
Inform the sound corresponding to the grade I-drop acoustics. The use of the opinion should be 10 (Pereira).
Inform the sound corresponding to the grade II listed-prejudice. The use of the opinion should be 10 (Pereira).
Grade III-Professional Deafness
Inform the sound corresponding to the grade III-occupational deafness. The use of the opinion should be 10 (Pereira).
Grade IV-Reduction in minimum degree
Inform the sound corresponding to the Grade IV-reduction in minimum degree. The use of the opinion should be 10 (Pereira).
Grade V-Reduction in average degree
Inform the sound corresponding to the Grade V-reduction in average degree. The use of the opinion should be 10 (Pereira).
Grade VI-Reduction in maximum degree
Inform the sound corresponding to the Degree I saw reduction in maximum degree. The use of the opinion should be 10 (Pereira).
The D.A.N.-non-occupational Diacusia
Inform the sound corresponding to the Damage-not diacusia. The use of the opinion should be 10 (Pereira).
INSS Method Guide
Inform the sound corresponding to the 0-Degree normal. The use of the opinion should be 11 (INSS).
Degree 1-Reduction in minimum degree
Inform the sound corresponding to the 1-Degree reduction in minimum degree. The use of the opinion should be 11 (INSS).
2-degree Reduction in average degree
Inform the sound corresponding to the 2-Degree reduction in average degree. The use of the opinion should be 11 (INSS).
3-degree Reduction in maximum degree
Inform the sound corresponding to the 3-Degree reduction in maximum degree. The use of the opinion should be 11 (INSS).
Inform the sound corresponding to the 4-Degree of hearing loss. The use of the opinion should be 11 (INSS).
Loss type Guide
Inform the opinion that features the conductive loss. The use of the opinion should be 07 (loss). Conductive hearing loss occurs when sound is not transmitted properly to the inner ear.
Inform the opinion that features the sensorineural loss. The use of the opinion should be 07 (loss). This loss is usually associated with age.
Inform the opinion that features mixed loss. The use of the opinion should be 07 (loss).
Davis and Silverman Method Guide
Inform the sound corresponding to the 0-Degree normal. The use of the opinion should be 12 (Davis & Silverman).
Inform the sound corresponding to the Grade 1-mild loss. The use of the opinion should be 12 (Davis & Silverman).
Inform the sound corresponding to the Grade 2-moderate loss. The use of the opinion should be 12 (Davis & Silverman).
Inform the sound corresponding to the Grade 3-severe loss. The use of the opinion should be 12 (Davis & Silverman).
Inform the sound corresponding to the Grade 4-deep loss. The use of the opinion should be 12 (Davis & Silverman).
Fowler Method Guide
The Fowler test is based on the subjective impressions that the patient has when it compares the feeling of intensity of a tone between the two ears.
Inform the opinion normality to the Fowler method. The use of the opinion should be 13.
Inform the opinion that features the loss in minimum degree. The use of the opinion should be 13.
Inform the opinion that features the loss in average degree. The use of the opinion should be 13.
Methodology for interpretation Fowler
For calculation of the hearing loss, in accordance with the law, added the table values corresponding to each frequency hearing loss, and the final value of the sum shall correspond to the hearing loss.
When it comes to bilateral loss using the formula proposed by the "Council on Physical Therapy" of the American Medical Association, which is based on the fact that there is, as a rule, a 7/8 of the good ear for the malfunction. The formula is as follows:
-
Bilateral loss = ((% loss of hearing better * 7) +% worse ear loss)/8
The opinions will be suggested according to the settings below.
For a single ear:
4%-Loss in minimum degree
8%-Loss in average degree
For both ears:
9%-Loss in minimum degree
18%-Loss in average degree