Note: This page was translated using automation resources with the purpose of providing content in your language more quickly. Consequently, it may have grammatical errors and similar situations. If the content is not useful in this state, in the page footer you can access the original material in Brazilian Portuguese and also give us opinions on this translation.
Security and Medicine / Medicine / Audiometry / Definitions

Audiometry Definitions

Aims to determine the required settings for the treatment of the audiometry tests. In this screen the settings for the audiometry item will be determined; we will indicate the opinions for the automatic interpretation of this exam in the folders; Portaria Method 19, Clinical, Pereira, INSS, Davis & Silverman, Fowler and Type of Loss.

Audiometry Guide

Final Exam Result

Valid information:

Consider the absence of the average

Used to calculate the averages 0.5 .1 .2 frequencies and 3, 4, 6 and airway also the calculation of logoaudiometria. Valid information:

Absence of Reply

To cater for cases where the audiometry reports are listed in printers that have black ink only, this field allows you to set the print form of the Green results when frequencies their response (SR), as follows:

  1. -Value corresponds to previous form, that is, prints the value without reply in green.
  2. Acronym SR (no reply)-the values without reply will be replaced by MR green in color.

Worse than Air bone

Used at the launch of the values of Bone frequencies:

Hours Default Home

Match the time of hearing that home must be fulfilled for audiométrico examination. This value should be at least 2:0 pm. To register a new audiométrico exam, will be proposed this value.

Audiometry

Inform the name of the default template of audiometry where will be presented the charts and results. The official model is SMAU002.GER. In audiometric tests results window you will find the Audiometry button to generate the report.

Monitoring Audiometry

Inform the name of the default template to be used in the issuance of tracking model audiometry. The official model is SMAU003.GER. In audiometric tests results window you will find the button Evolution to generate this report. Will display the selected results.

Offers fixed line on the chart

Allows you to list a boundary line of normalcy on audiométrico examination record.

Fixed line on the chart

Allows you to define what part of the line graph will be displayed. The allowed values are between -10 to 130.

Filing Frequency

Send Questionnaire

Valid information:

Yes, after generating the audiometry, model this model of the questionnaire will be generated.

N-no, will be raised only the model of audiometry.

Uses Meatoscopia/Otoscopy

Valid information:

 

Uses Logoaudiometria

Valid information:

Lim. Colour temp. Logoaudiometria

Enter a value to limit the intensity in his logoaudiometria. The "intensity" is located in Medicine/Audiometry/results, Result items folder, subfolder Logoaudiometria or Logoaudiometria folder, as indicated in the previous provision. The frequencies used to calculate the threshold are: 0.5-0.25-1-2.

Important

If the field is zero-valued, there will be no limit.

Features Immitanciometry Examinations Which Demonstrate

The immitanciometry examinations which demonstrate is the test which checked the conditions of the middle ear, more specifically the eardrum system-fusion, and via the Stapedius Reflex. Valid information:

Immitanciometry examinations which demonstrate

Inform the immitanciometry examinations which demonstrate the model that will be listed from the registration window of audiometric tests results, through the [Immitanciometry examinations which demonstrate]. The print template corresponds to SMAU004.GER.

Features Estapediano Reflex

Valid information:

Presents Weber

The Weber method uses the tuning fork where is installed in the midline of the front, the skullcap or with the incisor teeth. If the sound is perceived equally in both ears, hearing is normal or hearing loss is similar bilaterally and, in this case, it is said that Weber is indifferent. If the lateralizar sound to the ear of better hearing loss is sensorineural in the affected side. If the lateralizar sound to the ear more committed, the conductive loss is in the latter. Valid information:

Uses Clinical Method

Valid information:

Uses Method Pereira

Valid information:

Uses Method INSS

Valid information:

Uses kind of loss

Valid information:

Uses Method Davis & Silverman

Valid information:

Uses Fowler Method

Valid information:

Audiometry Results

Indicate whether the audiometry results will be considered by ear or by examination.

Important

Every time you change this field to ' 0 '-consider for examination to ' 1 '-consider for Ear, pressing the change button will be held a conversion in the information of the R108RES fields. TipExa, R108RES. NorAlt, R108RES. EvoRes and R108RES. SitRes (fields of the audiometry results right ear) will be duplicated for the fields TipEsq, ResEsq, EvoEsq and OcuEsq, respectively (fields for left ear).

Result Immitanciometry Examinations Which Demonstrate

When the field is with value "C-Complicance":

When the field is with value "F-Frequency":

Portaria Method Guide 19

Within the limits

Indicate the opinion that will be used on automatic interpretation of the test. The use of the opinion should be 8 (Ordinance 19).

Suggestive of PAINPSE (hearing loss Induced by High sound pressure levels)

Indicate the opinion that will be used on automatic interpretation of the test. The use of the opinion should be 8 (Ordinance 19).

Not suggestive of PAINPSE (hearing loss Induced by High sound pressure levels)

Indicate the opinion that will be used on automatic interpretation of the test. The use of the opinion should be 8 (Ordinance 19).

PAINPSE Trigger

Within limits: Indicate the opinion that will be used on automatic interpretation of the test. The use of the opinion should be 8 (Ordinance 19).

PAINPSE Trigger (hearing loss Induced by High sound pressure levels)

Indicate the opinion that will be used on automatic interpretation of the test. The use of the opinion should be 8 (Ordinance 19).

PAINPSE aggravation (hearing loss Induced by High sound pressure levels)

Indicate the opinion that will be used on automatic interpretation of the test. The use of the opinion should be 8 (Ordinance 19).

Clinical Method Guide

0-Normal degree

Inform the sound corresponding to the 0-Degree normal. The use of the opinion should be 9 (clinical method).

Grade 1-mild loss

Inform the sound corresponding to the Grade 1-mild loss. The use of the opinion should be 9 (clinical method).

Grade 2-Moderate Loss

Inform the sound corresponding to the Grade 2-moderate loss. The use of the opinion should be 9 (clinical method).

Degree 3-moderate/Severe Loss

Inform the sound corresponding to the Grade 3-moderate/severe loss. The use of the opinion should be 9 (clinical method).

Degree 4-severe loss

Inform the sound corresponding to the Grade 4-severe loss. The use of the opinion should be 9 (clinical method).

Degree 5-Deep Loss

Inform the sound corresponding to the 5-Degree deep loss. The use of the opinion should be 9 (clinical method).

Anacusia

Inform the sound corresponding to the type Anacusia. The use of the opinion should be 9 (clinical method). Anacusia means the complete loss of hearing.

Method Guide Pant

0-Normal degree

Inform the sound corresponding to the 0-Degree normal. The use of the opinion should be 10 (Pereira).

Grade I-Drop Acoustics

Inform the sound corresponding to the grade I-drop acoustics. The use of the opinion should be 10 (Pereira).

Grade II-Clinical Damage

Inform the sound corresponding to the grade II listed-prejudice. The use of the opinion should be 10 (Pereira).

Grade III-Professional Deafness

Inform the sound corresponding to the grade III-occupational deafness. The use of the opinion should be 10 (Pereira).

Grade IV-Reduction in minimum degree

Inform the sound corresponding to the Grade IV-reduction in minimum degree. The use of the opinion should be 10 (Pereira).

Grade V-Reduction in average degree

Inform the sound corresponding to the Grade V-reduction in average degree. The use of the opinion should be 10 (Pereira).

Grade VI-Reduction in maximum degree

Inform the sound corresponding to the Degree I saw reduction in maximum degree. The use of the opinion should be 10 (Pereira).

The D.A.N.-non-occupational Diacusia

Inform the sound corresponding to the Damage-not diacusia. The use of the opinion should be 10 (Pereira).

INSS Method Guide

0-Normal degree

Inform the sound corresponding to the 0-Degree normal. The use of the opinion should be 11 (INSS).

Degree 1-Reduction in minimum degree

Inform the sound corresponding to the 1-Degree reduction in minimum degree. The use of the opinion should be 11 (INSS).

2-degree Reduction in average degree

Inform the sound corresponding to the 2-Degree reduction in average degree. The use of the opinion should be 11 (INSS).

3-degree Reduction in maximum degree

Inform the sound corresponding to the 3-Degree reduction in maximum degree. The use of the opinion should be 11 (INSS).

Degree 4-hearing loss

Inform the sound corresponding to the 4-Degree of hearing loss. The use of the opinion should be 11 (INSS).

Loss type Guide

Conductive Loss

Inform the opinion that features the conductive loss. The use of the opinion should be 07 (loss). Conductive hearing loss occurs when sound is not transmitted properly to the inner ear.

Sensorineural Loss

Inform the opinion that features the sensorineural loss. The use of the opinion should be 07 (loss). This loss is usually associated with age.

Joint Loss

Inform the opinion that features mixed loss. The use of the opinion should be 07 (loss).

Davis and Silverman Method Guide

0-Normal degree

Inform the sound corresponding to the 0-Degree normal. The use of the opinion should be 12 (Davis & Silverman).

Grade 1-mild loss

Inform the sound corresponding to the Grade 1-mild loss. The use of the opinion should be 12 (Davis & Silverman).

Grade 2-Moderate Loss

Inform the sound corresponding to the Grade 2-moderate loss. The use of the opinion should be 12 (Davis & Silverman).

Degree 3-severe loss

Inform the sound corresponding to the Grade 3-severe loss. The use of the opinion should be 12 (Davis & Silverman).

Degree 4-Deep Loss

Inform the sound corresponding to the Grade 4-deep loss. The use of the opinion should be 12 (Davis & Silverman).

Fowler Method Guide

The Fowler test is based on the subjective impressions that the patient has when it compares the feeling of intensity of a tone between the two ears.

Normal

Inform the opinion normality to the Fowler method. The use of the opinion should be 13.

Loss in minimum degree

Inform the opinion that features the loss in minimum degree. The use of the opinion should be 13.

Loss in average degree

Inform the opinion that features the loss in average degree. The use of the opinion should be 13.

Methodology for interpretation Fowler

For calculation of the hearing loss, in accordance with the law, added the table values corresponding to each frequency hearing loss, and the final value of the sum shall correspond to the hearing loss.

When it comes to bilateral loss using the formula proposed by the "Council on Physical Therapy" of the American Medical Association, which is based on the fact that there is, as a rule, a 7/8 of the good ear for the malfunction. The formula is as follows:

The opinions will be suggested according to the settings below.

For a single ear:

4%-Loss in minimum degree

8%-Loss in average degree

For both ears:

9%-Loss in minimum degree

18%-Loss in average degree