Note: This page was translated using automation resources with the purpose of providing content in your language more quickly. Consequently, it may have grammatical errors and similar situations. If the content is not useful in this state, in the page footer you can access the original material in Brazilian Portuguese and also give us opinions on this translation.
Time and Cafeteria Control Module / Collectors / Codin 805/9000 / Commands

Commands

Through this option you can send commands to offline collectors Codin 805/9000.

In order to use the send routine of commands is necessary to follow the following steps:

  1. Install the sink application, PGRWIN, from which will be sent the commands (the same machine on which is installed the Time and Cafeteria Control module) and run the executable Application generator that comes with the PGRWIN, to generate the file for the sink with a name that can be up to 12 positions. This name will be entered in the record collector. Can be used the same name for all collectors, depending on the functionality of each sink.
  2. Report correctly the settings of the PGRWIN installed in Sinks > > 9000 > 805 CodinDefinitions.
  3. In Collectors> Central Management, register one or more Centralizers (ARL) to group the collectors. The centralizer code will be entered in the collector's register.
  4. In >Record Collectors, register all offline Codin collectors that will receive commands from the Control module and Cafeteria. The registration of collectors is necessary to inform the Central code management, the Number of Terminal (also known as alpha code), the name of the application of the Collector and the lists for each collector.
  5. Fill in the configuration (SeniorConfigCenter.exe) the camp site for collectors ' lists, informing the path where is installed the application PGRWIN.

After the above settings, can be made the commands and the generation ofLists.

Important

The PGRWIN version superior to the 3.06 version do not generate more processing status on the window. This is a limitation of the TCPBATCH application. EXE of telematics, and the Senior does not have what to do to work around this situation. Although not shown on the status, the commands are executed normally.

Codin collectors models 805/9000 produced by Intelligent Systems Telematics S/a.

Status

Returns the status of the collectors, as the options indicated.

Characteristics
It provides the following information:

Buffer
Tells how many records are in the normal area and in the area of backup of the memory of the terminal.

Communication
Provides the date and time of the last gathering took place and the number of retransmissions performed (how many times the terminal needed to relay a block to the PGR 805).

Errors
It provides the following information:


Codes Reports on which codes (application and lists) are loaded into the memory of the terminal. For each code that is in memory, it contains the name of the file, the time and date it was loaded, and the scan status, indicating if what is in the terminal memory corresponds to what was registered in the PGR 805.

Active Function
Shows the function that is active in the terminal.

In order for the collectors to be shown, enter the Group code and press Enter or Tab. It is also possible to show only some of the Collectors of the selected Group informing their codes in the field Collectors.

To return the status of the collectors, you must select them in the grid and click the Run.

Commands

This tab allows the sending of commands to the collector. In order for the collectors to be displayed in the grid, you must enter the Group code and press Enter.

To send the command, you must select the desired command type and the collectors to which it will be sent, and click Run. The available commands are:

Load

In this tab you can load lists for the collectors. For this, one must select the desired option and the collectors that will receive the list, and click the button Run. The types of lists available are:

  • If the name tag is present in the list, and the badge is equal to the list of tracks, this is considered valid.
  • If the badge is not on the list, however, the badge is equal to that stated in the application, is also considered valid.
  • If the name tag is present on the list, however, the badge is different, so is considered invalid and blocked the access.
  1. Have a history of badge open (holder or provisional).
  2. Are not parted with a situation that blocks access (field > prevchar= >= nextchar=>B>></MTLINGO>block access>> prevchar=>o> nextchar= >/=>> the register of the situation).</MTLINGO>
  3. Have permission for the clock (permissions are reported on the "Access"of the employee's cadastral form).

Collection

This guide allows you to collect the markings made on the collectors. To perform the collection, you must select the Collection Type and click on Run.

Normal Transfer
The system will collect the clocking events from the latest collection. That is, only collected the clocking events which have not yet been collected. After collected, the clocking events will be stored in files that are saved in the way informed the Codin 805 settings/9000.

Backup Transfer
Collects only the records already collected earlier and which are still in memory of the terminal. You must enter the desired period in the fields Initial date and Final date.

Normal Transfer w / Lock
Collects the markings that have not yet been collected and those already collected, according to the period Initial date and Final date.

Group
Inform the collectors group code containing the clocks for which you want to send commands. After informing the Group and press >Enter>, the collectors that he belong will be shown in the grid. Collector groups are registered in Collectors >Collectors groups.

Collectors
This field allows you to be informed a filter for the collectors that will be displayed in the grid. IE will only be shown to belong to the filter collectors informed here. After entering the filter, you must press Enter to apply it.


Collector Grid In this grid will be displayed the collectors belonging to the group of collectors informed in the field Group.

Sel
. Mark this column to indicate the collectors which will be sent the command.


Result In this field are shown the results of the operation being performed.

(missing or bad snippet)